BM
A tracheostomy (also called a tracheotomy) is an opening surgically created through the neck into the trachea (windpipe) to allow air to fill the lungs. After creating the tracheostomy opening in the neck, surgeons insert a tube through it to provide an airway and to remove secretions from the lungs. The tube helps breathing and helps clear mucus from the airway
CHENKANG
it is a protected suction tube (catheter) inside a sterile plastic sleeve. This is called a closed suction system or Ballard suction. Closed suction enables a clinician to clear the lungs of secretions whilst maintaining ventilation and minimizing contamination with the least possible disruption to the patient.
FORMED
Made of medical grade PE, Latex free, flexible with graduated marking provides depth indication to ensure correnct placement Curved tip with distal rounded smooth tip which allows the bougies to be inserted without damaging the soft tissue. Curved tip can be passed blindly into the tracheal when visualization of the glottis is inadequate to guide placement of endotracheal tube.Suitable for pediatric, child and adult.
HUAXING (CBI)
Choose the infusion pump of the corresponding specification according to the actual userequirements;2- Take out the infusion pump from the sterilization package, and check whether the connections of the infusion pump are firm before use;3- Open the protective cap of the dosing port, push the restrictor on the pipeline to the tightest, and use a sterile syringe to inject the liquid into the silicon capsule from the dosing port4- After the dosing is completed, after confirming that there is no liquid leakage of each part, cover the protective cap of the dosing port and open the restrictor card; see that the liquid is connected to the conical joint after the liquid flows out;5- The self-control infusion pump needs to be placed for 3-5 minutes after adding the medicine, and then use a sterile syringe to insert the instantaneous dosing port of the automatic control device, extract the residual air in the pipeline, and then suck 1~2ml of the liquid medicine and inject it from the instantaneous dosing port, At this time, the liquid medicine can be seen flowing out of the joint, Pipe joints or other connecting devices begin to relieve pain or perform other treatments. Discard all components after use.
HUAXING (PCA)
Choose the infusion pump of the corresponding specification according to the actual useRequirements.2- Take out the infusion pump from the sterilization package, and check whether the connections of the infusion pump are firm before use.3- Open the protective cap of the dosing port, push the restrictor on the pipeline to the tightest, and use a sterile syringe to inject the liquid into the silicon capsule from the dosing port.4- After the dosing is completed, after confirming that there is no liquid leakage of each part, cover the protective cap of the dosing port and open the restrictor card; see that the liquid is connected to the conical joint after the liquid flows out.5- The self-control infusion pump needs to be placed for 3-5 minutes after adding the medicine, and then use a sterile syringe to insert the instantaneous dosing port of the automatic control device, extract the residual air in the pipeline, and then suck 1~2ml of the liquid medicine and inject it from the instantaneous dosing port, At this time, the liquid medicine can be seen flowing out of the joint, Pipe joints or other connecting devices begin to relieve pain or perform other treatments. Discard all components after use.
Medispine
Spinal needle
Intended for spinal anaesthesia.
Ultra fine quincke tip for better dura puncture appreciation and to prevent post dura
puncture headache.
Color-coded hub-stylet (International standard) for fast detection of the needle size.
Optimal sized stylet prevents tissue coring and obstruction of the needle size.
Transparent hub for fast detection of CSF.